AXISP7216VideoEncoder
Connectors
I/Oterminalconnector
6-pinterminalblockfor:
•DigitalInput
•DigitalOutput
•Auxiliarypowerandground
(GND)
FunctionPinNotes
Specications
GND
1
Ground
3.3VDC
Power
2
Canbeusedtopowerauxiliaryequipment.
Note:Thispincanonlybeusedaspowerout.
Maxload=250mA
Digitalinput—ConnecttoGNDtoactivate,
orleaveoating(unconnected)todeactivate.
0to+40VDC Congurable
(Inputor
Output)
3–
6
Digitaloutput—Internalconnection
togroundwhenactivated,oating
(unconnected)whendeactivated.Ifused
withaninductiveload,e.g.arelay,adiode
Maxload=100mA
Maxvoltage=+40VDC