Chapter II-12 — Graphs
II-246
Manual Axis Ranges
When a graph is first created, it is in autoscaling mode. In this mode, the axis limits automatically adjust to
just include all the data. You can set the axis limits to fixed values by selecting the Manual Min and Manual
Max checkboxes. When you select one of these checkboxes, both are automatically selected. You can elect
to fix just one end of an axis range by de-selecting one of these checkboxes. The other end will then be
adjusted by Igor to include the minimum or maximum value of the data.
The fixed limits are set by editing the values in the boxes below the Manual Min and Manual Max check-
boxes. Initially these boxes are set to the automatic values of the limits.
There are a number of other ways to set the Min and Max limits. Clicking the Expand 5% button expands
the range between the min and the max by 5 percent. This has the effect of shrinking the graph traces plotted
on the axis by 5%. Clicking the Swap button exchanges the Min and Max parameters. This has the effect of
reversing the ends of the axis. You can plot waves upside-down or backwards. This works for linear, log
and date/time axes. If you don’t want the axis limits to be fixed, use the Reverse Axis checkbox in the
Autoscale Settings area.
An additional way to set the Min and Max parameters is to select a wave from the list and use the Quick
Set buttons. If you click the X Min/Max quick set button then the minimum and maximum X values of the
selected wave are transferred to the parameter boxes. If you click the Y Min/Max quick set button then the
minimum and maximum Y values of the selected wave are transferred to the parameter boxes. If you spec-
ified the full scale Y values for the wave then you can click the Full Scale quick set button. This transfers the
wave’s Y full scale values to the parameter boxes. The full scale Y values can be set using the Change Wave
Scaling item in the Data menu.
Automatic Axis Ranges
When the Manual Min and Manual Max checkboxes are not selected the given axis is in autoscaling mode.
In this mode the axis limits are determined by the data values in the waves displayed using the selected
axis. The items inside the Autoscale box control the method used to determine the axis range:
You can cause an autoscaled axis to be reversed by selecting the “Reverse axis” checkbox.
Autoscale mode usually sets the axis limits using all the data in waves associated with the traces that use
the axis. This can be undesirable if the associate horizontal axis is set to display only a portion of the total
X range. Select the Autoscale Only Visible Data checkbox to have Igor use only the data included within the
horizontal range for autoscaling.
Overall Graph Properties
You can specify certain overall properties of a graph by choosing Modify Graph from the Graph menu. This
brings up the Modify Graph dialog. You can also get to this dialog by double-clicking in any blank area
outside the plot rectangle.
Forces the end of the axis that is closest to zero to be
exactly zero.
The default mode. Axis range is set to the minimum and
maximum data values of all waves plotted using this axis.
Extends axis range to the next major tick mark.
Like “Round to nice values” but also ensures that traces
are inset from the ends of the axis.
The default mode.
Forces zero to be in the middle of the axis range.