Autoloader
Advanced Dicing Technologies Ltd.
9.1-6
9.1.2.1.1 Axes
The Axes subsection of the CassComp section of the Setup &
Diagnostics tree includes the following:
Elevator
Finger
The Setup & Diagnostics screens for each axis are very similar. These
screens enable the user to initialize the individual axes, perform self tests
and manually position the axis at a specific location.
Elevator and Finger Axes
Select an axis from the Setup & Diagnostics tree to display the following:
The lower right pane (identical for Elevator and Finger screens) displays a
representation of the travel of the selected axis, with its home position on
the left and the farthest distance it can travel on the right.