LNC-M8000
Function
214 寶元數控精密股份有限公司
LNC Technology Co., Ltd.
I_NO => I No., value range****, unit:N/A
1~2 Card1 EPCIO LI1~2
11~12 Card2 EPCIO LI1~2 ~ 51~52 Card6 EPCIO LI1~2
101~106 Card1 CPLD LI1~6
111~116 Card2 CPLD LI1~6 ~ 151~156 Card6 CPLD LI1~6
path Get if I Latch happend(0:N,1:Y), unit:N/A
#1 = R_I_LATCH(0,101); /* Get CPLD first I signal, if triggered, #1Value=1 */
R_I_LATCH_COOR(PATH,I_NO,AXIS)
This function will stop interpretation automatically.(TypeⅠ)
PATH =>Path No., value range 0 ~6, unit:N/A.
0:Current path, 1~6:First path~6th path.
I_NO => I No., value range****, unit:N/A
1~2 Card1 EPCIO LI1~2
11~12 Card2 EPCIO LI1~2 ~ 51~52 Card6 EPCIO LI1~2
101~106 Card1 CPLD LI1~6
111~116 Card2 CPLD LI1~6 ~ 151~156 Card6 CPLD LI1~6
AXIS=>Appoint axis number, value range1~6, unit:N/A
path Get I Latch coordinate, unit=mm
#1 = R_I_LATCH_COOR(0,101,1); /* Get CPLDfirst I point LATCH MACHINE coordinate
value */