LNC-M8000
Function
216 寶元數控精密股份有限公司
LNC Technology Co., Ltd.
Converts the input value to the maximum metric or inch unit mode. Metric mode (mm/min), inch
mode (inch/min).
#1 = LEN_STD(0,2,25.4); /* If 2 axis is linear axis and its SBK in under inch mode, #1Value=1
inch */
LEN_STD_R(PATH,AXIS,R_No)
R Length Value Regularization
This function will stop interpretation automatically.(TypeⅠ)
PATH =>Path No., value range 0 ~6, unit:N/A.
0:Current path, 1~6:First path~6th path.
AXIS=>Appoint axis number, value range0~6, unit:N/A
0:Convert directly. 1~32:follow path axis situation to change
R_No=> R location NO., value range0 ~ 129999, 1000000 ~ 3999999, unit:N/A
Converts the input value to the maximum metric or inch unit mode. Metric mode (mm/min), inch
mode (inch/min).
Alarm:
-1 =>R value NO. is over range.
#1 = LEN_STD_R(0,2,1); /* If 2 axis is linear axis and its SBK in under inch mode,
R[1]=25400, #1Value=1 inch */
LEN_STD_R_F(PATH,AXIS,R_No)
Pre-read R valuelength Value
Regularization
PATH =>Path No., value range 0 ~6, unit:N/A.
0:Current path, 1~6:First path~6th path.
AXIS=>Appoint axis number, value range0~6, unit:N/A
0:Convert directly. 1~32:follow path axis situation to change
R_No=> R location NO., value range0 ~ 129999, 1000000 ~ 3999999, unit:N/A
Converts the input value to the maximum metric or inch unit mode. Metric mode (mm/min), inch
mode (inch/min).
Alarm:
-1 =>R value NO. is over range.
#1 = LEN_STD_R(0,2,1); /* If 2 axis is linear axis and its SBK in under inch mode, R[1]=25400,
#1Value=1 inch */
8.10 In position function
Feedrate In Position Check
PATH =>Path No., value range 0 ~6, unit:N/A.
0:Current path, 1~6:First path~6th path.