LNC-M8000
Variables
寶元數控精密股份有限公司 231
LNC Technology Co., Ltd.
9 Variables
This chapter is to explain whole series of INT mode.
Version: Milling machine INT mode mill_int_Ver03.01.01
9.1 Variables range menu
End-user global variables
Only system
MACRO
Read/write
By user authority
Read/write
Shared path end-user
global variables
Shared path system
global variables
Only system
MACRO
Read/write
By user authority
Read/write
9.2 Number range classification
(1). Local Variables:
#00:always empty.
#01 ~ #199:read/write
For every level’s program, there are 199 local variables. If you cancel this level’s program, variables will
be canceled. But if you press RESET, it will go back to main program level, and main level’s local
variables was determined by P#50004.1. If you press RESET, you can not cancel this. But if you reboot
the controller, every level’s local variables will be canceled.
(2). Global Variables:
All levels of the program shared this common variable at single path.
@0000:Always empty.
@0001 ~ @0999:User global variables range, only suitable for its path, value clear will be determined by
P# 50005.1 whether booting or pressing RESET.
@1000 ~ @1999:System global variables range, only suitable for its path system MACRO, value clear
will be determined by pressing RESET.
@5000 ~ @5999:User global variables range, suitable for all paths, value clear will be determined by P#
Komentáře k této Příručce